Company News
Installation of high efficiency filter specification
Category:Company NewsReleased Date:2015-06-16

High efficiency filter installation specifications have a lot of pieces, we a section to resolve. The first is the size of its outlet must meet our design requirements, must be cleaned before installation, when we need to be installed in a clean room to replace the lost filter outlet, plus the gasket at the seams. After we replaced the filter outlet, but also with short pipe buried, short tube and ceiling inevitably some gaps, these gaps need plugging good place to spend the opening of the plastic film and tape. The second is a comprehensive cleanup before installation, including clean rooms, air purification room, as well as technical dissection too.
    Article 3 Before installing the high efficiency filter to clean up those places, then we have to run the pre-air conditioning, until everything is normal and we will find a lot of dust from the operation of the air conditioning was out, this time in the future we can once again sweep assured installed.
    Article IV is the time of installation must take place carefully carefully, because severe vibration and impact is very easy it is considered destroyed. For each filter resistance size we should be rational distribution, the difference generally being fixed resistance and the resistance between the average should not be greater than 5%, as well as the overall framework must be balanced, the permissible error is only 1 mm, because directly related to the effect of the device.
    The space between the high efficiency filter and the frame must be sealed, because it is the air filter, if not sealed, then simply do not achieve results, the device loses its meaning. General will use the seal, or glass, plastic, etc. If the gasket is then recommended thickness not more than 8 mm, and the compression ratio control between 25% -30%, you can also use tank seal, but the height of the liquid surface To meet the designer's standards, can not appear the phenomenon of liquid penetration. Now seal doors and windows has become the first choice, and the effect is really good, it uses EPDM rubber material, can play a good role in a closed, install high efficiency filter when the frame above there will be an arrow pointing to the direction of gas flow that it should, if vertically mounted, we should ensure that at least the filter of a line to be perpendicular to the ground, so as to ensure that the installation is not the slightest problem, as long as we want to achieve this effect.

Back
Keywords:
版权所有 2015.昆山顺峰净化设备科技有限公司. Technical support:优网科技 Sitemap
收缩
  • QQ咨询

  • 联系我们